106 lines
3.1 KiB
JavaScript
106 lines
3.1 KiB
JavaScript
|
const debug = require('debug')('log4js:clustering');
|
||
|
const LoggingEvent = require('./LoggingEvent');
|
||
|
const configuration = require('./configuration');
|
||
|
|
||
|
let disabled = false;
|
||
|
let cluster = null;
|
||
|
try {
|
||
|
// eslint-disable-next-line global-require
|
||
|
cluster = require('cluster');
|
||
|
} catch (e) {
|
||
|
debug('cluster module not present');
|
||
|
disabled = true;
|
||
|
}
|
||
|
|
||
|
const listeners = [];
|
||
|
|
||
|
let pm2 = false;
|
||
|
let pm2InstanceVar = 'NODE_APP_INSTANCE';
|
||
|
|
||
|
const isPM2Master = () => pm2 && process.env[pm2InstanceVar] === '0';
|
||
|
const isMaster = () =>
|
||
|
disabled || (cluster && cluster.isMaster) || isPM2Master();
|
||
|
|
||
|
const sendToListeners = (logEvent) => {
|
||
|
listeners.forEach((l) => l(logEvent));
|
||
|
};
|
||
|
|
||
|
// in a multi-process node environment, worker loggers will use
|
||
|
// process.send
|
||
|
const receiver = (worker, message) => {
|
||
|
// prior to node v6, the worker parameter was not passed (args were message, handle)
|
||
|
debug('cluster message received from worker ', worker, ': ', message);
|
||
|
if (worker.topic && worker.data) {
|
||
|
message = worker;
|
||
|
worker = undefined;
|
||
|
}
|
||
|
if (message && message.topic && message.topic === 'log4js:message') {
|
||
|
debug('received message: ', message.data);
|
||
|
const logEvent = LoggingEvent.deserialise(message.data);
|
||
|
sendToListeners(logEvent);
|
||
|
}
|
||
|
};
|
||
|
|
||
|
if (!disabled) {
|
||
|
configuration.addListener((config) => {
|
||
|
// clear out the listeners, because configure has been called.
|
||
|
listeners.length = 0;
|
||
|
|
||
|
({
|
||
|
pm2,
|
||
|
disableClustering: disabled,
|
||
|
pm2InstanceVar = 'NODE_APP_INSTANCE',
|
||
|
} = config);
|
||
|
|
||
|
debug(`clustering disabled ? ${disabled}`);
|
||
|
debug(`cluster.isMaster ? ${cluster && cluster.isMaster}`);
|
||
|
debug(`pm2 enabled ? ${pm2}`);
|
||
|
debug(`pm2InstanceVar = ${pm2InstanceVar}`);
|
||
|
debug(`process.env[${pm2InstanceVar}] = ${process.env[pm2InstanceVar]}`);
|
||
|
|
||
|
// just in case configure is called after shutdown
|
||
|
if (pm2) {
|
||
|
process.removeListener('message', receiver);
|
||
|
}
|
||
|
if (cluster && cluster.removeListener) {
|
||
|
cluster.removeListener('message', receiver);
|
||
|
}
|
||
|
|
||
|
if (disabled || config.disableClustering) {
|
||
|
debug('Not listening for cluster messages, because clustering disabled.');
|
||
|
} else if (isPM2Master()) {
|
||
|
// PM2 cluster support
|
||
|
// PM2 runs everything as workers - install pm2-intercom for this to work.
|
||
|
// we only want one of the app instances to write logs
|
||
|
debug('listening for PM2 broadcast messages');
|
||
|
process.on('message', receiver);
|
||
|
} else if (cluster && cluster.isMaster) {
|
||
|
debug('listening for cluster messages');
|
||
|
cluster.on('message', receiver);
|
||
|
} else {
|
||
|
debug('not listening for messages, because we are not a master process');
|
||
|
}
|
||
|
});
|
||
|
}
|
||
|
|
||
|
module.exports = {
|
||
|
onlyOnMaster: (fn, notMaster) => (isMaster() ? fn() : notMaster),
|
||
|
isMaster,
|
||
|
send: (msg) => {
|
||
|
if (isMaster()) {
|
||
|
sendToListeners(msg);
|
||
|
} else {
|
||
|
if (!pm2) {
|
||
|
msg.cluster = {
|
||
|
workerId: cluster.worker.id,
|
||
|
worker: process.pid,
|
||
|
};
|
||
|
}
|
||
|
process.send({ topic: 'log4js:message', data: msg.serialise() });
|
||
|
}
|
||
|
},
|
||
|
onMessage: (listener) => {
|
||
|
listeners.push(listener);
|
||
|
},
|
||
|
};
|